Quantcast 3. OUTRIGGER JACKS, MAST OR BOOM OPERATION SLOW OR ABNORMAL

Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: 3. OUTRIGGER JACKS, MAST OR BOOM OPERATION SLOW OR ABNORMAL
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
2. MHC WILL NOT OPERATE WITH REMOTE CONTROLS
Up
TM-9-2320-364-10 Truck Tractor Line Haul 52 000 GVWR 6x4 M915A2 Truck Tractor Light Equipment Transporter (Let) Manual
Next
5. BOOM OPERATION JERKY OR WILL NOT TELESCOPE IN OR OUT
TM 9-2320-364-10 3-32      Table 3-1.  Troubleshooting - CONT. Malfunction Test or Inspection Corrective Action MATERIAL HANDLING CRANE (MHC) (CONT). 3. OUTRIGGER JACKS, MAST OR BOOM OPERATION SLOW OR ABNORMAL. NOTE If high idle does not work, but is required for mission, remove chock block from stowage and place on throttle control to achieve desired high idle.   Notify Unit Maintenance when mission is completed. Step 1.    Ensure if Engine High Idle Speed switch (1) is latched and engine is at high idle (1275 rpm). Step 2.    Check main hydraulic reservoir for fluid level. If level is low, notify Unit Maintenance. If level is OK and problem persists, notify Unit Maintenance. 4. BOOM WILL NOT RAISE OR LOWER. Step 1.    Check that outrigger jacks are firmly deployed.  If not, lower outrigger jacks until front suspension is unloaded and tires do not bulge. Step 2.    Check that load is not over the load limit shown on range diagram (Para 2-30). If load is over range diagram, lower load to ground and reduce load to correct weight. If load is OK and problem remains, notify Unit Maintenance.