Page Title: QUICK RELEASE VALVE TEST
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 9-2320-364-20-2      2-1811 (1)   Disconnect air line 2668 from service relay valve No. 2. (2)   Connect 0 to 160 psi (0 to 1103 kPa) gage to air line 2668. (3)   Apply service brakes while observing pressure gage (TM 9-2320-364-10). (a)   If there are not 125 4 psi (861 28 kPa) present at air line 2668, perform Steps (4) and (5) below and replace quick release valve (Para 12-39). (b)   If there are 125 4 psi (861 28 kPa) at air line 2668, quick release valve is OK. (4)   Release service brakes. (5)   Remove gage and connect air line 2668 to service relay valve No. 2. QUICK RELEASE VALVE TEST Wear safety goggles when performing leakage injury due to high pressure air. Apply brake pedal (TM 9-2320-364-10). (1)   If service brakes on Axles No. 3 through No. 5 do not apply, fault not corrected.  Release brake pedal and notify DS Maintenance. (2)   If service brakes on Axles No. 3 through No. 5 do apply, fault has been corrected.  Release brake pedal. VERIFY REPAIR

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business