46.  LOW AIR/HYDRAULIC OIL ALARM DOES NOT OPERATE
Up
TM-9-2320-364-20-2 Truck Tractor Line Haul 52 000 GVWR 6x4 M915A2 Truck Tractor Light Equipment Transporter (Let) Manual
Next
46.  LOW AIR/HYDRAULIC OIL ALARM DOES NOT OPERATE (CONT) - TM-9-2320-364-20-2_794
TM 9-2320-364-20-2      2-1569 (1)   Remove instrument panel from truck (Para 7-13). (2)   Set multimeter select switch to ohms. (3)   Is continuity measured on wire 1276 between voltmeter (12V) and buzzer? (a)   If there is no continuity, repair wire 1276 (see schematic Fig 2-28) or replace harness (Para 7-14). (b)   If there is continuity, go to Step 2 of this fault. CONTINUITY TEST Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry or tools contact positive electrical circuits a direct short may result.  Damage to equipment, injury or death to personnel may occur.