TM 9-2320-364-20-3 2-2896 4.  FAN, LHS, WINCH AND CRANE DO NOT OPERATE (CONT). 2. Tighten connections or replace hose(s) (Para 20-3; see schematic Fig 2-70). Verify repair, go to Step 7 of this Fault. YES NO Truck hoses OK. Crane hoses and tubes leaking   or damaged. Pump driveshaft faulty. High pressure filter clogged. Strainer clogged. Main hydraulic filter clogged. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Visual inspection. Leaking crane hoses will not allow pump to deliver maximum pressure. Are crane hoses and tubes free of leaks and damage?