TM 9-2320-364-20-3 2-2900 4.  FAN, LHS, WINCH AND CRANE DO NOT OPERATE (CONT). 4. Replace hydraulic filter and clean or replace bypass valve (Para 20-6, 20-7 and 20-8).   Verify repair, go to Step 7 of this Fault. YES NO Truck hoses OK. Crane hoses and tubes OK. Pump driveshaft OK. High pressure filter clogged. Strainer clogged. Main hydraulic filter clogged. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Visual inspection. Clogged high pressure filter and bypass valve will not allow pressure to multi-function manifold. 5. Replace strainer (Para 20-13). Verify repair, go to Step 7 of this Fault. YES NO Truck hoses OK. Crane hoses and tubes OK. Pump driveshaft OK. High pressure filter OK. Strainer clogged. Main hydraulic filter clogged. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Visual inspection. Clogged strainer will not allow supply oil to pump. Are high pressure hydraulic filter and bypass valve free of restrictions? Is main hydraulic reservoir strainer free of clogging?

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business