TM 9-2320-364-20-3
2-2918
6. FAN SPEED DOES NOT LOWER FROM HIGH SPEED TO LOW SPEED (CONT).
7.
Repair wire 1538 (see
schematic Fig 2-67)
or notify DS
Maintenance.
Verify repair, go to
Step 19 of this Fault.
YES
NO
Heater blower motor operates,
indicating CB15 OK.
Fan operates at low speed with
hydraulic selector switch in
AUTO or CRANE/SRW
position.
Fan operates at low speed with
throttle position switch
depressed.
Wire 1933 between MC59 and
MC128 OK.
Wire 1932 between MC59 and
MC61 OK.
Wire 1932 between MC61 and
MC128 OK.
Temperature sensor OK.
Wire 1538 faulty.
Wire 1435 from fan controller
faulty.
Wire 1935 or 1936 between
MC59 and MC76 faulty.
Temperature switch faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If wire 1538 is loose, faulty, or
shorted to ground, 22 to 28 vdc
will not be input to fan controller
from CB15.
8.
Repair wire 1435
(see schematic
Fig 2-67) or notify
DS Maintenance.
Verify repair, go to
Step 19 of this Fault.
YES
NO
Heater blower motor operates
indicating CB15 OK.
Fan operates at low speed with
hydraulic selector switch in
AUTO or CRANE/SRW
position.
Fan operates at low speed with
throttle position switch
depressed.
Wire 1933 between MC59 and
MC128 OK.
Wire 1932 between MC59 and
MC61 OK.
Wire 1932 between MC61 and
MC128 OK.
Temperature sensor OK.
Wire 1538 OK.
Wire 1435 from fan controller
faulty.
Wire 1935 or 1936 between
MC59 and MC76 faulty.
Temperature switch faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
If wire 1435 is loose or faulty,
fan controller will not be
grounded.
Are 22 to 28 vdc measured on
wire 1538 at connector MC73,
terminal A?
Is continuity measured on
wire 1435 between connector
MC73, terminal B and a
known good ground?
|