TM 9-2320-364-20-3
2-2017
(1) Disconnect connector MC109 from
CTIS front manifold.
(2) Set multimeter select switch to
ohms.
(3) Connect jumperwire between
wire 1056 on CTIS controller
connector MC111, terminal 1 and a
known good ground.
(4) Is there continuity between
connector MC109, terminal 1 and
front manifold ground braid?
(a) If there is no continuity, repair
wire 1056 (see schematic
Fig 2-48) or notify DS
Maintenance and perform
Steps (6) through (9) below.
(b) If there is continuity, wire 1056
is OK.
(5) Check continuity on remaining wires
and terminals using Steps (2)
through (4) above. The wires and
corresponding terminals are listed
below (see schematic Fig 2-48).
1057(2)
Shield(8)
1058(3) 1061(6) 1064(9)
1059(4) 1062(7) 1065(10)
1063(5) to ground (MC 109 only)
(6) Remove jumperwire.
(7) Connect connector MC111 on back
of CTIS controller.
(8) Connect connector MC109 on CTIS
front manifold.
(9) Install instrument panel and sunshield
with ten screws.
CONTINUITY TEST
NOTE
Terminal (5) at MC 111 is plugged and does not
connect to Terminal (5) on MC 109.
|