TM 9-2320-364-20-3      2-2129 (1)   Disconnect connector from transducer on rear manifold. (2)   Set multimeter select switch to volts dc. (3)   Connect positive (+) multimeter lead to blackwire terminal at transducer connector. (4)   Connect negative (–) multimeter lead to rear manifold ground braid. (5)   Turn ON ENGINE switch. (TM 9-2320-364-10). (6)   Push CTIS START button. (a)   If 4.7 to 5.2 vdc are not present, turn OFF ENGINE switch and replace rear manifold (Para 13-9). (b)   If 4.7 to 5.2 vdc are present, turn OFF ENGINE switch and go to Step 15 of this Fault. VOLTAGE TEST Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry or tools contact positive electrical circuits, a direct short may result.  Damage to equipment, injury or death to personnel may occur.