2.  AIR DRYER(S) AND/OR AFTERCOOLER CONTINUALLY PURGE (CONT) - TM-9-2320-364-20-3_324
Up
TM-9-2320-364-20-3 Truck Tractor M1074 and M1075 Palletized Load System (PLS) Manual
Next
3.  COMPRESSOR FAILS TO UNLOAD (AIR SYSTEM PRESSURE BUILDS UP TO MORE THAN 129 PSI (889 KPA))
TM 9-2320-364-20-3      2-2203 (1)   Start engine (TM 9-2320-364-10). (2)   Run at idle for 10 minutes. (3)   Observe air pressure gage. (a)   If air pressure gage does not read 125 4 psi (861 28kPa), fault not corrected.  Perform Step (4) below and notify DS Maintenance. (b)   If air pressure gage reads 125 4 psi (861 28 kPa), fault has been corrected. (4)   Turn OFF ENGINE switch. VERIFY REPAIR