TM 9-2320-364-20-3
2-2279
(1) Set multimeter select switch to ohms.
(2) Is there continuity between
LHS NO TRANS lamp electrical
connector wire 1435 terminal
and a known good ground?
(a) If there is no continuity, repair wire
1435 (see schematic Fig 2-52)
and perform Steps (3) and (4)
below or notify DS Maintenance.
(b) If there is continuity, wire 1435
is OK.
(3) Connect electrical connector to LHS
NO TRANS lamp socket.
(4) Install instrument panel and sunshield
with ten screws.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|