TM 9-2320-364-20-3
2-2282
3. LHS OVERLOAD LIGHT DOES NOT OPERATE.
INITIAL SETUP
1.
Is LHS OVERLOAD lamp free
of damage?
Replace lamp
(Para 7-24). Verify
repair, go to Step 10 of
this Fault.
START
YES
NO
Nothing.
LHS OVERLOAD lamp faulty.
Wire 1479 faulty.
Wire 1460 faulty.
Overload differential pressure
switch faulty.
LHS control assy faulty.
Wire 1726 faulty.
Wire 1435 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
Faulty lamp will not operate.
2-28. LOAD HANDLING SYSTEM (LHS) TROUBLESHOOTING (CONT).
Tools and Special Tools
Tool Kit, General Mechanics: Automotive
(Item 74, Appendix G)
STE/ICE-R (optional) (Item 3, Appendix G)
Multimeter (Item 44, Appendix G)
Jumperwire
Materials/Parts
Lockwasher (4) (Item 180, Appendix F)
Adhesive (Item 8, Appendix C)
Equipment Condition
Engine OFF, (TM 9-2320-364-10)
Parking brake applied, (TM 9-2320-364-10)
Wheels chocked, (TM 9-2320-364-10)
References
TM 9-2320-364-10
TM 9-4910-571-12&P
WARNING
Personnel Required
Two
Read WARNING
on Page 2-2283
|