TM 9-2320-364-20-3
2-2331
(1) Set multimeter select switch
to ohms.
(2) Loosen screw and disconnect
connector from one of the safe
lowering valves on the RH side
of the LHS.
(3) Is there continuity between either
right side safe lowering valve
harness connector, terminal 2 and a
known good ground.
(a) If there is no continuity, repair
wire 1475 (see schematic
Fig 2-52) or notify DS
Maintenance.
(b) If there is continuity, perform
Steps (4) through (7) below.
(4) Connect connector to safe lowering
valve.
(5) Tighten connector screw and coat
head of connector screw with
adhesive.
(6) Loosen screw and disconnect
connector from the remaining safe
lowering valve on the RH side
of the LHS.
(7) Is there continuity between
remaining right side safe lowering
valve harness connector, terminal 2
and a known good ground?
(a) If there is no continuity, repair
wire 1475 (see schematic
Fig 2-52) or notify DS
Maintenance.
(b) If there is continuity, perform
Steps (8) through (10) below.
(8) Remove jumperwire from main
junction box terminal 10 and ground.
(9) Connect connector to safe lowering
valve.
(10) Tighten connector screw and coat
head of connector screw with
adhesive.
CONTINUITY TEST
Remove all jewelry such as rings, dog
tags, bracelets, etc. If jewelry or
tools contact positive electrical circuits,
a direct short may result. Damage to
equipment, injury or death to personnel
may occur.
Adhesive, solvents, and sealing compounds
can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. To
avoid injury or death, keep away from open
fire and use in a well-ventilated area. If
adhesive, solvent, or sealing compound gets
on skin or clothing, wash immediately with
soap and water.
|