TM 9-2320-364-20-3
2-2373
(1) Set hydraulic selector switch to MAN
HA position (TM 9-2320-364-10).
(2) Set multimeter select switch to ohms.
(3) Is there continuity between harness
connector MC93, terminal D and
harness connector MC94, terminal E?
(a) If there is no continuity, replace
hydraulic selector switch
(Para 7-31).
(b) If there is continuity, hydraulic
selector switch is OK.
(4) Connect harness connector MC94 to
hydraulic selector switch connector.
(5) Connect harness connector MC93 to
hydraulic selector switch connector.
(6) Install ECB side panel and six screws.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|