13.  LHS DOES NOT LOAD IN AUTO MODE
Up
TM-9-2320-364-20-3 Truck Tractor M1074 and M1075 Palletized Load System (PLS) Manual
Next
13.  LHS DOES NOT LOAD IN AUTO MODE (CONT) - TM-9-2320-364-20-3_564
TM 9-2320-364-20-3      2-2441 Check clearance between proximity switch and compression frame. (1)   If clearance is more than .135 in. (3.43 mm) or less than .115 in. (2.92 mm), proximity switch is not adjusted correctly.  Adjust proximity switch (main frame down) (Para 7-39). (2)   If clearance is between .135 in. (3.43 mm) and .115 in. (2.92 mm), proximity switch adjustment is OK. PROXIMITY SWITCH CLEARANCE TEST