Quantcast CONTINUITY TEST - TM-9-2320-364-20-3_643

Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: CONTINUITY TEST
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
1.  NO CRANE FUNCTIONS WORK USING REMOTE CONTROL (CONT) - TM-9-2320-364-20-3_642
Up
TM-9-2320-364-20-3 Truck Tractor M1074 and M1075 Palletized Load System (PLS) Manual
Next
1.  NO CRANE FUNCTIONS WORK USING REMOTE CONTROL (CONT) - TM-9-2320-364-20-3_644
TM 9-2320-364-20-3      2-2521 Is there continuity between remote control connector, terminal B and a known good ground? (1)   If there is no continuity, repair green wire between hookup and ground terminal strip in crane junction box (see schematic Fig 2-58) or notify DS Maintenance. (2)   If there is continuity, wire is OK. CONTINUITY TEST Remove all jewelry such as rings, dog tags, bracelets etc.  If jewelry or tools contact positive electrical circuits, a direct short may result.  Damage to equipment, injury or death to personnel may occur. (1)   Set multimeter select switch to ohms. (2)   Is there continuity between terminal H at one end of cable and terminal H at other end? (a)   If there is no continuity, replace cable. (b)   If there is continuity, go to Step (3) below. (3)   Is there continuity between terminal B at one end of cable and terminal B at other end? (a)   If there is no continuity, replace cable. (b)   If there is continuity, perform Step (4) below and go to Step 4 of this Fault. (4)   Connect remote control unit cable to truck hookup and remote control unit connector. CONTINUITY TEST