TM 9-2320-364-20-3 2-2540 2.  HOIST WILL NOT LOWER USING REMOTE CONTROL UNIT (CONT). 7. Repair white wire (see schematic Fig 2-58) or notify DS Maintenance. Verify repair, go to Step 9 of this Fault. YES NO Hoist operates using manual   control lever mounted on   crane. At least one other remote   control function operates. Remote control unit   harness OK. Controller switch OK. Controller circuit card OK. Remote control unit cable OK. Orange wire from truck remote   control connector outlet to   terminal 16 OK. White wire from terminal 16 to   solenoid faulty. Solenoid black wire faulty. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Continuity test. STE/ICE-R #91. If there is no continuity, 22 to 28 vdc will not be present at solenoid. WARNING Is continuity measured between hoist DOWN solenoid harness connector, terminal 1 and crane junction box terminal 16? Read   WARNING on Page 2-2541

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business