TM 9-2320-364-20-3
2-2614
6. BOOM WILL NOT TELESCOPE IN USING REMOTE CONTROL UNIT (CONT).
8.
Repair black wire
(see schematic
Fig 2-58) or notify
DS Maintenance.
Verify repair, go to
Step 9 of this Fault.
YES
NO
Telescope operates using
manual control lever.
At least one other remote
control function operates.
Remote control unit harness
OK.
Controller switch OK.
Controller circuit card OK.
Remote control unit cable OK.
White wire from truck remote
control connector outlet to
terminal 12 OK.
White wire from terminal 12 to
solenoid OK.
Solenoid black wire faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
If there is no continuity, solenoid
will not be grounded.
WARNING
Is continuity measured
between telescope IN
solenoid harness connector,
terminal 2 and black wire?
Read WARNING
on Page 2-2615
|