TM 9-2320-364-20-3
2-2717
Is there continuity between main
hydraulic pressure valve connector,
terminal 2 and a known good ground?
(1) If there is no continuity, repair
connector black wire (see
schematic Fig 2-58) or notify DS
Maintenance.
(2) If there is continuity, connect
connector, and tighten screw. Fault
not corrected, notify DS
Maintenance.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical