4.  ALL TIRES ON AXLES NO. 1 AND NO. 2 WILL NOT DEFLATE (CONT).
Up
TM-9-2320-364-20-3 Truck Tractor M1074 and M1075 Palletized Load System (PLS) Manual
Next
5.  EXCESS INFLATION TIME AXLES NO. 1 AND NO. 2, CTIS GREEN INDICATOR FLASHES TOO LONG OR CONTINUALLY.
TM 9-2320-364-20-3      2-1963 (1)   Start engine (TM 9-2320-364-10). (2)   Set CTIS controller to CROSS- COUNTRY. (3)   As assistant pushes CTIS START button, observe tires. (a)   If tires do not deflate, fault not corrected.  Turn OFF ENGINE switch and notify DS Maintenance. (b)   If tires deflate, fault has been corrected. (4)   Turn OFF ENGINE switch. VERIFY REPAIR