TM 9-2320-364-20-3
2-2863
(1) Is there continuity on wire 1724
between connector MC93, terminal A
and AUX HYD light connector?
(a) If there is no continuity, repair
wire 1724 (see schematic
Fig 2-52) or notify DS
Maintenance. Perform Step (2)
below.
(b) If there is continuity, wire 1724
is OK.
(2) Install connectors MC93 and MC94 on
hydraulic selector switch connectors.
CONTINUITY TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
|