TM 9-2320-364-20-4      2-3069 (1)   Remove quick disconnect from mounting bracket (Para 21-12). (2)   Inspect quick disconnect safety nut release. (3)   Inspect moveable components for dirt, sticking, or any other physical damage. (a)   If quick disconnect is damaged, repair or replace (Para 21-12). (b)   If quick disconnect is not damaged, quick disconnect is OK. (4)   Install quick disconnect (Para 21-12). VISUAL INSPECTION High pressure hydraulics [oil under 3700 psi (25,512 kPa) pressure] operate this equipment.  Refer to vehicle operator and maintenance manuals for hydraulic oil pressure.  Never disconnect any hydraulic line or fittings without first dropping pressure to zero.  A high pressure oil stream can pierce body and cause severe injury to personnel. QUICK DISCONNECT