TM 9-2320-364-20-4 2-3114 4. Repair wire 1785 (see schematic Fig 2-75) or notify DS Mainte- nance. Verify repair, go to Step 7 of this Fault. YES NO 12 vdc present at polarity   protection terminal B. Wire 1785 from 12 vdc polarity   protection to MC136 is OK. Wire 1785 from MC136 to   CB27 is OK. Circuit breaker CB27 is OK. Wire 1785 from CB27 to   connector MC136 terminal A   faulty. Wire 1785 from MC136 to   MC129 faulty. Wire 1785 from MC136 to   MC130 faulty. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Voltage test. STE/ICE-R #89. If 10 to 14 vdc are not measured, wire 1785 is faulty. Are 10 to 14 vdc measured on wire 1785 at MC136 terminal A? 3.  LOSS OF INTERFACE POWER 12 VDC (CONT). WARNING Read   WARNING on Page 2-3115