TM 9-2320-364-20-4 2-3126 3. Replace circuit breaker CB28 (Para 21-15). Verify repair, go to Step 7 of this Fault. YES NO 24 vdc present at polarity   protection terminal B. Wire 1784 from 24 vdc polarity   protection to MC136 is OK. Wire 1784 from MC136 to   CB28 OK. Circuit breaker CB28 faulty. Wire 1784 from CB28 to   MC136 faulty. Wire 1784 from MC136 to   MC129 faulty. Wire 1784 from MC136 to   MC130 faulty. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Voltage test. STE/ICE-R #89. If 22 to 28 vdc are not present, circuit breaker CB28 is faulty. Are 22 to 28 vdc measured on wire 1784 at circuit breaker CB28? 4.  LOSS OF INTERFACE POWER 24 VDC (CONT). WARNING Read   WARNING on Page 2-3127