TM 9-2320-364-20-4      2-3159 Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry or tools contact positive electrical circuits, a direct short may result.  Damage to equipment, injury or death to personnel may occur. CHU CONTROL BOX CONNECTOR MC82B (1)   Disconnect harness connector MC82B from CHU control box. (2)   Set multimeter select switch to ohms. (3)   Is there continuity between wire 1464, terminal 87A and connector, MC82B, terminal D? (a)   If there is no continuity, repair wire 1464 (see schematic Fig 2-79) or notify DS Maintenance. (b)   If there is continuity, wire 1464 is OK. (4)   Connect harness connector MC82B to CHU control box. CONTINUITY TEST 1464 87A R51 86 87A 87 85 30 A B C D E F G H J K L M N P R S T D R52 R51 R50