Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: CONTINUITY TEST
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 9-2320-364-20-4      2-3161 R52 R51 R50 Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry or tools contact positive electrical circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur. CHU CONTROL BOX SCREWS CHU CONTROL BOX (1)   Set multimeter select switch to ohms. (2)   Is there continuity between relay R51, terminal 85 and known good ground? (a)   If there is no continuity, notify DS Maintenance. (b)   If there is continuity, repair wire 1496 between connector MC190, terminal A and connector MC185, terminal G (see schematic Fig 2-80) or notify DS  Maintenance. (3)   Install relay R51 (Para 21-23). (4)   Position CHU control cover on box and tighten four screws. CONTINUITY TEST 85 1496 R51 86 87A 87 85 30