Tachometer mounting bracket
TM 9-2320-364-20-4      7-63 Both battery gages are removed in the same way. (11) Remove wires 1276 or 1702 (26) and 1435 (27)  from rear of battery gage (28). (12) Disconnect gage light connector 1052 (29) from rear of battery gage (28). NOTE All light connectors are removed the same way. Make sure light bulbs and light bulb sockets stay with warning light housings. (13) Disconnect 19 light connectors (30) from rear of 19 warning light housings (31).