TM 9-2320-364-20-4 7-208      7-56. DDEC II ENGINE COLD PLATE/ELECTRONIC CONTROL MODULE (ECM) REPLACEMENT (CONT). (9) Install two wiring harness connectors (20) on ECM (14) and tighten two screws (19). Use caution while installing connectors from ECM.  The ECM has plastic retainers that may break if connectors are not properly installed. NOTE Ensure locking tangs are locked in place when installing wiring harness connectors. (10) Install three wiring harness connectors (18) on ECM (14). NOTE If only installing cold plate, perform Steps (11) and (12). (11) Install two preformed packings (16), plate (17), plastic fitting block (8) and two screws (15) on engine cold plate (12). Tighten screws 84 to 108 lb-in (9 to 12 N.m). (12) Install engine cold plate (12) and six screws (13) on electronic control module (14).  Tighten screws 156 to 204 lb-in (17 to 23 N.m).