TM 9-2320-364-20-5 18-84      18-17.  SELF-RECOVERY WINCH (SRW) CABLE REPLACEMENT (CONT). (3) Remove cable assembly (5) from front cable tensioner (6) and front cable guide (7). b. Installation. Wire cable assembly can become frayed or contain broken wires.  Wear heavy leather-palmed work gloves when handling wire cable assembly.  Frayed or broken cable can and cause injury to personnel. Never let moving wire cable assembly slide through hands, even when wearing gloves.  A broken wire could cut through glove and cause injury to personnel. (1) Route cable assembly (5) through front cable guide (7) and front cable tensioner (6).