TM 9-2320-364-34-2      10-17 (8) Remove air supply and adapter from lower supply port (8). (9) Remove air pressure gage from lower delivery port (7) on backside of treadle valve (1). (10) Remove two pipe plugs (4) from upper ports (5) and (6) on backside of treadle valve (1). (11) Install two pipe plugs (4) in lower ports (7) and (8) on backside of treadle valve (1). (12) Install air pressure gage in upper delivery port (6) on backside of treadle valve (1). Air pressure should be between 80 to 120 psi (552 to 827 kPa). Failure to comply may result in damage to equipment. (13) Install air supply line and adapter in upper supply port (5). 7 8 1 5 6 4 ADAPTER AIR SUPPLY LINE AIR PRESSURE GAGE ADAPTER AIR SUPPLY LINE AIR PRESSURE GAGE 1 5 6 4 8 7