TM 9-2320-364-34-3 18-194 18-13.  CONTAINER HANDLING UNIT (CHU) KIT INSTALLATION (CONT). (268) Start engine, set hydraulic selector switch (292) to MAN H.A. and raise hook arm (77) until sensor plate (295) covers approximately half of proximity switch (302) (TM 9-2320-364-10). (269) Shut OFF engine. (270) Using feeler gage, adjust clearance between CHU proximity switch (302) and sensor plate (295) to 0.125 in.  0.01 in. (3.18 mm  0.25 mm) and tighten nuts (303). (271) Disconnect batteries (TM 9-2320-364-20). 292 295 301 0.125 IN.  0.01 IN. (3.18 MM  0.25 MM) 77 303 303