TM 9-2320-364-34-4      20-231 (23) Measure widest part of plastic gage with measuring strip.  Width must be minimum of 0.0014 in. (0.0356 mm) and maximum of 0.0055 in. (0.1397 mm).  If greater, replace upper and lower bearing shells (12). (24) Wipe plastic gage from five main bearing journals (16) or bearing shells (12) and apply lubricating oil to those surfaces. (25) Position five bearing caps (9) and (14) on crankshaft (6). (26) Strike bearing caps (9) and (14) with soft-face hammer.