Quantcast BLACKOUT STOPLIGHT(S) DO NOT OPERATE. (Cont) -725550236

 

Click here to make tpub.com your Home Page

Page Title: BLACKOUT STOPLIGHT(S) DO NOT OPERATE. (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
BLACKOUT STOPLIGHT(S) DO NOT OPERATE. (Cont) -725550235
Up
TM-9-2330-385-14 Palletized Load System Trailer (PLST) Model M1076 Manual
Next
BLACKOUT STOPLIGHT(S) DO NOT OPERATE. (Cont) -725550237
TM 9-2330-385-14
7. BLACKOUT STOPLIGHT(S) DO NOT OPERATE (CONT).
8.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Truck electrical system OK.
Voltage test.
All other trailer lights operate.
Taillights operate indicating
REASON FOR QUESTION
LED composite light ground
Are 22 to 28 vdc measured on
is OK.
If 22 to 28 vdc are not present at
front junction box at
Blackout stoplight OK.
front junction box terminal 18,
terminal 18?
Blackout stoplight lamp OK.
blackout taillight will not operate.
Wire 1678/23-28 OK.
24 vdc cable OK.
Connector MC15 OK.
LED composite light OK.
Ground wire 1435 OK.
Replace front junction
POSSIBLE PROBLEMS
NO
Front junction box faulty.
Verify repair, go to
Wire 1678C-18 faulty.
Step 10 of this Fault.
Rear junction box faulty.
YES
4-94

Privacy Statement - Press Release - Copyright Information. - Contact Us