Quantcast ALL MARKER LIGHTS DO NOT OPERATE (S/N YB6122 075 AND UP). (Cont) -725550483

 

Click here to make tpub.com your Home Page

Page Title: ALL MARKER LIGHTS DO NOT OPERATE (S/N YB6122 075 AND UP). (Cont)
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

Share on Google+Share on FacebookShare on LinkedInShare on TwitterShare on DiggShare on Stumble Upon
Back
ALL MARKER LIGHTS DO NOT OPERATE (S/N YB6122 075 AND UP). -725550482
Up
TM-9-2330-385-14 Palletized Load System Trailer (PLST) Model M1076 Manual
Next
ALL MARKER LIGHTS DO NOT OPERATE (S/N YB6122 075 AND UP). (Cont) -725550484
TM 9-2330-385-14
Remove all jewelry such as rings, dog tags,
bracelets, etc. If jewelry or tools contact
positive electrical circuits, a direct short
may result. Damage to equipment, injury or
death to personnel may occur.
VOLTAGE TEST
(1) Disconnect 12 vdc cable from
connector MC16.
(2) Set multimeter select switch to
volts vdc.
(3) Connect positive (+) multimeter lead
to pin B on 12 vdc cable.
(4) Connect negative (- ) multimeter lead
-
to pin A on 12 vdc cable.
(5) While assistant turns ON ENGINE
switch and turns on LIGHT switch,
observe multimeter,
(TM 9-2320-364-10).
(a) If 10 to 14 vdc are not present,
perform Steps (6) and (7) below
and repair (Para 4-31) or replace
(Para 2-9) 12 vdc cable.
(b) If 10 to 14 vdc are present, 12 vdc
cable is OK.
(6) Turn off LIGHT switch.
(7) Turn OFF ENGINE switch.
(8) Connect 12 vdc cable to connector
MC16.

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc.
6230 Stone Rd, Unit Q Port Richey, FL 34668

Phone For Parts Inquiries: (727) 493-0744
Google +