NOTE
Align alignment pin in back
of lens support with cutouts
in bracket and gasket.
Ground wire only installed
on center light.
(4)
Install gasket (11), lens support (3) and wire
1435-34 (10) on bracket (12) with two
screws (9) and locknuts (8).
(5)
Connect 1012-33 connector (6) to 489
connector (7) on right light.
(6)
Connect 1012-32 connector (6) to 489
connector (7) on center light.
(7)
Connect 1012-31 connector (6) to 489
connector (7) on left light.
Corrosion inhibitor contains
alkali. Do not get in eyes; wear
goggles/safety glasses when
using. Avoid contact with skin.
In case of contact, immediately
wash area with soap and water.
If eyes are contacted, flush eyes
with large amounts of water for
at least 15 minutes and get
immediate medical attention.
(8)
Apply anti-corrosion silicone compound to
inside of lamp socket (5).
(9)
Install bulb (4) in lamp socket (5).
(10) Install lens (2) with two screws (1).
c.
Follow-On Maintenance:
Connect intervehicular cables, (Para 2-9).
Remove wheel chocks, (Para 2-20).
END OF TASK