4-44. DRAWBAR AIR ASSIST CONTROL REPLACEMENT (CONT).
b.
Installation.
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors and
are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use
in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing,
wash immediately with soap and water.
Use sealing compound sparingly and only on threads. Do not apply compound on hose
connections. Damage to equipment may result.
NOTE
Perform Steps (1) through (8) for Model A.
(1)
Apply sealing compound on threads of
plug (15).
(2)
Install plug (15) in valve (10).
(3)
Apply sealing compound on threads of
reducers (12), (13) and (14).
(4)
Install reducers (12), (13) and (14) on valve
(10).
(5)
Apply sealing compound on threads of
elbows (4), (5) and (6).
(6)
Install elbows (4), (5) and (6) on reducers
(12), (13) and (14).
(7)
Install valve (10) on turntable (11) with two
screws (7), lockwashers (8) and washers (9).
(8)
Install air lines 2225 (1), 2228 (2) and 2226
(3) on elbows (4), (5) and (6).
4-2  2
-458.