Next
AIR LINE REPLACEMENT.
TM 9-2330-385-14
NOTE
Ensure that the screw holes are
at the top of the valve during
installation.
(14)
Install valve (5) on bracket (8) with two
screws (7) and locknuts (6).
(15)
Install washer (4) and nut (3) on shaft (2).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and
water.
(16)
Apply sealing compound to threads of
shaft (2).
(17)
Turning to the right, install knob (1) on
shaft (2).
c.
Follow-On Maintenance:
Charge air system, (Para 2-22).
Check for air leaks, (Para 4-7).
Remove wheel chocks, (Para 2-20).
END OF TASK