4-50. RELIEF VALVE REPLACEMENT (CONT).
(3)
Remove fitting (6) from valve (1).
(4)
Remove adapter (5) from valve (1).
b.
Installation.
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a well-
ventilated area. If adhesive,
solvent, or sealing compound gets
on skin or clothing, wash
immediately with soap and
water.
Use sealing compound sparingly
and only on threads. Do not
apply compound on hose
connections. Damage to
equipment may result.
NOTE
Install cable ties as required.
(1)
Apply sealing compound on threads of
adapter (5).
(2)
Install adapter (5) on valve (1).
(3)
Apply sealing compound on threads of
fitting (6).
(4)
Install fitting (6) on valve (1).