DOOR ASSEMBLY REPLACEMENT - CONTINUED
0015 00
INSTALLATION - CONTINUED
NOTE
Perform step 8 if strap assembly was removed from door frame.
If door frame is new, refer to Crew Protection Kit Installation Instructions (WP 0037 00) for instruc-
tions on drilling hole in door frame for installation of strap assembly.
8.
Install strap assembly (4) to door frame with two bushings (7), washer (6), bolt (5), washer (8), and new locknut (9).
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can cause lung irritation.
Contact with skin can cause dermatitis. Wear gloves and safety goggles and use product in a well-ventilated
area away from open flame. If ingested, keep individual calm and seek medical attention. DO NOT induce
vomiting. If contact with skin or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW
local policy and ordinances. Failure to follow this warning may cause injury to personnel.
9.
Apply thread adhesive to bolt (2). Install strap assembly (4) to door assembly (1) with washer (3) and bolt (2).
1
2,3
7,8,9
(HIDDEN)
5,6
(HIDDEN)
4
417-048
10.
Adjust latch as necessary (WP 0016 00).
11.
Verify correct operation of door assembly.
12.
If removed, install reflector and outside mirror to door assembly (TM 9-2320-364-20).