Table 4-1. Field Level Preventive Maintenance Checks and Services (Semi-Annual) (Continued)
CHAPTER 5. FIELD LEVEL TROUBLESHOOTING

Air Conditioning System Nsn 4120-01-526-9158 P/N 3528349 For Truck, Tractor M1074/M1075 Palletized Load System Page Navigation
  24    25    26    27    28  29  30    31    32    33    34  
img
DRAFT
TB 9-2320-364-13&P-1
FIELD LEVEL PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) -
Continued
Table 4-1.
Field Level Preventive Maintenance Checks and Services (Semi-Annual) (Continued)
Location
Item
Not Fully Mission
Interval
Item to
Procedure
No.
Capable if:
Check/Service
PLSAC116
2
Semi-
AC System
NOTE
Annual
Heater/evaporator shown removed for clarity.
(a) Clean AC evaporator core (1); check for
damage.
(b) Clean AC condenser core (2); check for
damage.
END OF WORK PACKAGE