TB 9-2320-364-13&P-1
AC HEATER/EVAPORATOR BLOWER OPERATES BUT NO COLD AIR FROM
DUCTS DURING AC OPERATIONS - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
9.
KNOWN INFO
TEST OPTIONS
Read WARNING on
Power to fan control switch OK.
Visual inspection.
Blower operates.
REASON FOR QUESTION
Is defrost cable free from
damage and binding?
If defrost cable is binding or
damaged, the defrost
louver may not be
damaged.
positioned correctly for AC
Temperature control switch temperature
operations.
probe OK.
AC harness wire 1155 OK.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
OK.
AC condenser motor red wire OK.
Replace defrost
AC condenser motor ground wire OK.
NO
AC condenser motor OK.
Verify repair, go to
Step 29 of this fault.
OK.
YES
OK.
Fan control switch OK.
Wire 1156 OK.
(AC Does Not Cool or Cools
Temperature control switch OK.
Inadequately).
AC harness wire 1435 OK.
AC harness wire 1154 OK.
Low pressure switch OK.
AC harness wire 1156 OK.
AC harness wire 1158 OK.
High pressure switch OK.
Heater cable OK.
AC cable OK.
POSSIBLE PROBLEMS
Defrost cable faulty.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0012-18