DRAFT
TB 9-2320-364-13&P-1
AC HEATER/EVAPORATOR BLOWER OPERATES BUT NO COLD AIR FROM
DUCTS DURING AC OPERATIONS - Continued
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
WARNING
24.
KNOWN INFO
TEST OPTIONS
Read WARNING on
Power to fan control switch OK.
Voltage test.
Blower operates.
REASON FOR QUESTION
Are 22 to 28 vdc measured on
AC condenser assembly
If 22 to 28 vdc are not
damaged.
harness green wire at AC
measured, AC condenser
assembly harness green
condenser fan motor solenoid
Temperature control switch temperature
wire is faulty.
probe OK.
terminal, when fan control
Heater cable OK.
switch is set to an on position
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
and temperature control
AC cable OK.
switch is set to the coldest
Defrost cable OK.
temperature position?
AC harness wire 1154 OK.
Low pressure switch OK.
High pressure switch OK.
AC harness wire 1158 OK.
Repair AC condenser
AC harness wire 1435 OK.
assembly harness
AC harness wire 1155 OK.
green wire (see
NO
Fan control switch OK.
repair, go to Step 29
Wire 1156 OK.
of this fault.
Temperature control switch OK.
YES
AC harness wire 1156 OK.
OK.
AC condenser motor red wire OK.
OK.
AC condenser motor OK.
POSSIBLE PROBLEMS
faulty.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
faulty.
AC condenser motor solenoid faulty.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0012-48