TM 9-2320-364-10
2-98
Table 2-3. Operators Preventive Maintenance Checks
and Services (After) - CONT.
Location
Item
No.
Interval
Item to
Check/
Service
Procedure
Not Fully Mission
Capable if:
51
After
Right Side
Air
Reservoirs
Check that air reservoirs (1), are
secure and there are no air leaks and
damage. Pull cable (2) and drain
reservoir until all water is drained.
Air leaks are present.
NOTE
Load Handling System and crane (if equipped) must be in stowed
position when taking reservoir fluid level reading, or incorrect fluid
level reading will be obtained.
The ladder is needed for the following procedures.
52
After
Hydraulic
Reservoir
Check hydraulic reservoir fluid
level indicator (1). If oil level is
within the FULL band, the quantity
of hydraulic oil is safe for operation.
Class III leak is
evident.
|