TM 9-2320-364-10
2-116
Table 2-4. Operators Preventive Maintenance Checks
and Services (Weekly) - CONT.
Location
Item
No.
Interval
Item to
Check/
Service
Procedure
Not Fully Mission
Capable if:
NOTE
Engine panel must be open for item 78.
78
Weekly
Alternator
Belts
(a) Check alternator belts (1) for
cracking, fraying, and breaks.
Check for tightness. Play should
be about 1/2 in. (13 mm).
(b) Check pulleys (2) for cracks
and damage. Close access panel.
Any belt is broken
or cracked to the
belt fiber, has more
than one crack (1/8
in. [3.2 mm] in
depth or 50 percent
of belt thickness) or
has frays more than
two in. (51 mm)
long. Any pulleys
cracked or damaged.
|