TM 9-2320-364-10
2-345
Do not operate crane unless both outrigger jacks are properly
set up. Truck could turn over causing serious injury or death.
Operator should be stationed to be able to see load at all times
during crane operation. Operate crane from RH or LH remote
control station if load is not visible from main crane control
panel. Boom and load moving out of control could cause
serious injury or death.
Do not operate mast control lever until boom is raised
approximately 45 degrees. Otherwise, boom nose can be
driven down into crane structure and damage will result.
NOTE
Mast will not erect if boom angle is significantly greater
than 45 degrees.
(4)
Observe boom angle indicator (20) and operate BOOM control lever (21) in
UP position until boom (22) is approximately 45 degrees above horizontal.
|