TM 9-2320-364-10
2-710
2-45. SELF-RECOVERY WINCH (SRW) (CONT).
(2)
Removal.
(a)
Ensure there is slack in cable (4).
(b)
Remove screw (2) from snatch block (1).
(c)
Move plate (3) to side to open snatch block (1).
Always wear heavy gloves when handling cables. Never let
cable run through hands; frayed cables can cut. Failure to
comply may result in injury to personnel.
(d)
Remove cable (4) from snatch block (1).
(e)
Close plate (3) and align holes in snatch block (1).
(f)
Install screw (2) in snatch block (1).
(g)
Return snatch block (1) to stowage.
(h)
Continue with self-recovery operations.
|