TM 9-2320-364-10 2-774      2-57.  EMERGENCY PROCEDURES (CONT). c. Crane Emergency Procedures. (1) Crane emergency operation with electrical failure: Do not try to operate any electrical equipment on truck or crane if electrical failure has occurred.  Damage to equipment could result. NOTE This procedure will provide emergency hydraulic power to lower crane and load when electrical power has failed. Failure of hydraulic system will stop operation of any crane, winch or hydraulic motor on truck.  All cranes and winches are equipped with automatic locking mechanisms to hold cranes and winches in position they were in before hydraulics failed. (a) Twist and pull out MHC Main Hydraulic Override Valve (1).  Remove safety wire (2) and push in and hold MHC Hydraulic System Manual Override button (3). (b) Stow crane (Para 2-30). (c) Notify Unit Maintenance.