TM 9-2320-364-10      2-23 Figure 2-9.  Side Panel Assembly Controls and Indicators - CONT. Key Control or Indicator Function 1 Hydraulic Selector Switch - Cont.  Manual Hook Arm (MAN H.A.) LHS manual hook arm setting is used when automatic sequencing is not operating.  This setting bypasses the automatic sequencing circuit to manually operate the Hook Arm only.  Manual Main Frame (MAN M.F.) LHS manual main frame setting is used when automatic sequencing is not operating.  This setting bypasses the automatic sequencing system to operate the Main Frame only.  Manual Transport (MAN TRANS) if auto sequence has electrical failure, this position must be selected if the truck is to travel.  Crane/Self-Recovery Winch (CRANE/SRW) used to switch hydraulic power to either the Crane or Winch.