(1) Disconnect transmission connector
MC19 at transmission bulkhead
connector.
(2) Connect breakout harness
transmission end connector to
transmission bulkhead connector.
(3) Set multimeter select switch to ohms.
(4) Read resistance between terminal C
and terminal T of breakout harness
connector.
(a) If 9 to 20 ohms resistance are not
measured, wiring inside
transmission and solenoid A is
faulty. Notify DS Maintenance.
(b) If 9 to 20 ohms resistance are
measured, go to Step (5) below.
(5) Is there continuity between breakout
harness connector, terminal C and a
known good ground?
(a) If there is no continuity, wiring
inside transmission and solenoid
A is OK. Go to Step 2 of
this Fault.
(b) If there is continuity, wiring inside
transmission and/or Solenoid A is
faulty. Notify DS Maintenance.