TM 9-2320-364-20-2
2-958
1. ENGINE FAILS TO CRANK (CONT).
15.
Repair wire 1045 (see
schematic Fig 2-24) or
notify DS
Maintenance.
Verify repair, go to
Step 20 of this Fault.
YES
NO
22 to 28 vdc register on 24 vdc
volt meter indicating wire 1055
between DUVAC and starter
motor is OK.
Batteries OK.
ENGINE switch OK.
Wire 1021 OK.
Wire 1871 OK.
Diode M36 OK.
Wire 231 OK.
Wire 210A OK.
Wires 208/209 OK.
NEUTRAL relay R11 OK.
Wire 1281 OK.
Wire 1021A OK.
Wire 1435 OK.
Magnetic switch R27 OK.
Wire 1139 OK.
Wire 1045 faulty.
Wire 1138 faulty.
Start ground wire faulty.
Starter motor solenoid faulty.
Starter motor faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If 22 to 28 vdc are not
measured, wire 1045 is faulty.
WARNING
16.
Repair wire 1138 (see
schematic Fig 2-24).
Verify repair, go to
Step 20 of this Fault.
YES
NO
22 to 28 vdc register on 24 vdc
volt meter indicating wire 1055
between DUVAC and starter
motor is OK.
Batteries OK.
ENGINE switch OK.
Wire 1021 OK.
Wire 1871 OK.
Diode M36 OK.
Wire 231 OK.
Wire 210A OK.
Wires 208/209 OK.
NEUTRAL relay R11 OK.
Wire 1281 OK.
Wire 1021A OK.
Wire 1435 OK.
Magnetic switch R27 OK.
Wire 1139 OK.
Wire 1045 OK.
Wire 1138 faulty.
Start ground wire faulty.
Starter motor solenoid faulty.
Starter motor faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
If ground is not measured,
wire 1138 is faulty.
WARNING
Are 22 to 28 vdc measured on
wire 1045 at starter solenoid
with ENGINE switch held in
START position?
Is wire 1138 to starter
grounded?
Read WARNING
on Page 2-959
Read WARNING
on Page 2-959
|