Page Title: VOLTAGE TEST
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 9-2320-364-20-2      2-1027 (1)   Connect positive (+) multimeter lead to wire 1020 at circuit breaker terminal. (2)   Connect negative (–) multimeter lead to a known good ground. (3)   Turn ON ENGINE switch (TM 9-2320-364-10). (a)   If there are not 22 to 28 vdc present, turn OFF ENGINE switch, and go to Step 8 of this Fault. (b)   If there are 22 to 28 vdc present turn OFF ENGINE switch, and replace circuit breaker (Para 7-16). VOLTAGE TEST Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry or tools contact positive electrical circuits, a direct short may result.  Damage to equipment, injury or death to personnel may occur. (1)   Connect positive (+) multimeter lead to wire 1020 at DUVAC. (2)   Connect negative (–) multimeter lead to a known good ground. (3)   Turn ON ENGINE switch (TM 9-2320-364-10). (a)   If 22 to 28 vdc are not present, turn OFF ENGINE switch, and repair wire 1020 between DUVAC and ENGINE switch (see schematic Fig 2-23) or notify DS Maintenance. (b)   If 22 to 28 vdc are present, wire 1020 is OK. (4)   Turn OFF ENGINE switch. VOLTAGE TEST

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business